Summary for Test 2018-09-10-2-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213133
DEA: 021H9404
EFIS: 0216000158
DIST-CO-RTE-PM02-SHA-5,273-R52.1,17.1
Award Date04/05/2018
Closeout Date01/09/2019
Work DescriptionBRIDGE JOINT SEALS AND STRUCTURAL CONCRETE.
Location DescriptionSHASTA COUNTY ON ROUTE 5 AT SACRAMENTO RIVER BRIDGE OVERHEAD AND ON ROUTE 273 AT SACRAMENTO RIVER BRIDGE
QA Service Level1 (Verified on 05/23/2018)

Sample Information

Sample Taken Date09/10/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2018
Sample typeQuality Assurance A brief description of the sampleBar Lock Couplers
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byD Last name of sampler or witnessed byMann
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor Dayton Superior Transportation Laboratory (TL) NumberC287084
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelBar Lock
Coating StandardsASTM A775 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A150815 Rebar Heat Number(s)3500000194
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-09-10-2
DIME Test ID: 2018-09-10-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-09-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/11/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
14C01#5/16mm0.3102942594919Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 9/12/2018