Summary for Test 2018-09-10-2-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213133 DEA: 021H9404 EFIS: 0216000158 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5,273-R52.1,17.1 |
Award Date | 04/05/2018 |
Closeout Date | 01/09/2019 |
Work Description | BRIDGE JOINT SEALS AND STRUCTURAL CONCRETE. |
Location Description | SHASTA COUNTY ON ROUTE 5 AT SACRAMENTO RIVER BRIDGE OVERHEAD AND ON ROUTE 273 AT SACRAMENTO RIVER BRIDGE |
QA Service Level | 1 (Verified on 05/23/2018) |
Sample Information
Sample Taken Date | 09/10/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/11/2018 |
Sample type | Quality Assurance | A brief description of the sample | Bar Lock Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Mann |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Nucor Dayton Superior | Transportation Laboratory (TL) Number | C287084 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dayton Superior | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5 | Coupler Model | Bar Lock |
Coating Standards | ASTM A775 epoxy | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | A150815 | Rebar Heat Number(s) | 3500000194 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-09-10-2
DIME Test ID: 2018-09-10-2-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-09-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/11/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 4 | C01 | #5/16mm | 0.31 | 0 | 29425 | 94919 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 9/12/2018 ✔