Summary for Test 2018-08-30-1-7

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 212573
DEA: 010B5504
EFIS: 0112000137
DIST-CO-RTE-PM01-MEN-162-16.2
Award Date09/28/2017
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT ROADWAY, CONSTRUCT SOLDIER PILE AND TIEBACK WALL
Location DescriptionMENDOCINO COUNTY ON ROUTE 162 1 MILE EAST OF MIDDLE FORK EEL RIVER BRIDGE
QA Service Level1 (Verified on 10/03/2017)

Sample Information

Sample Taken Date08/30/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/31/2018
Sample typeVerification A brief description of the sampleanchor bolts
The quantity of what the sample constitutes6 and 5 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCT METS QA INSPECTOR Telephone number of sampler801-669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-177-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)DL171103150,DL17105664,10459880 Nut Mfg. Lot Number(s)n/a
Washer Mfg. Lot Number(s)n/a Bolt SpecificationA449
Bolt Length(s)6" and 4" Nut Specificationn/a
Washer Specificationn/a FinishHDG
Diameter/Size1/2" x 4" , 5/8" x 6" Bolt Mfg. Lot Number79139,79141,97405,97217,97406
Rocap Test Requirement(s)none Lubricant Requirements(s)none

Test Details

DIME Sample ID: 2018-08-30-1
DIME Test ID: 2018-08-30-1-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-09-18

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/07/2018
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AA449 All Thread Axial0.1419189628413362912182617287A449 All Thread

General comments (publicly viewable) (Max 1000 characters): A449 All Thread
Test Graph
Source: Partner Data Point File

Test was verified on 9/11/2018