Summary for Test 2018-05-16-15-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 211705
DEA: 024G3804
EFIS: 0214000006
DIST-CO-RTE-PM02-TRI-299-0.0/8.3
Award Date11/30/2016
Closeout Date01/02/2019
Work DescriptionPLACE RUBBERIZED HOT MIX ASPHALT, GUARDRAIL, AND SOME DRAINAGE
Location DescriptionTRINITY COUNTY AT AND NEAR SALYER FROM HUMBOLDT COUNTY LINE TO 0.6 MILE EAST OF GRAY CREEK ROAD
QA Service Level1 (Verified on 10/25/2017)

Sample Information

Sample Taken Date05/16/2018 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/17/2018
Sample typeVerification A brief description of the sample1/2-inch RHMA-G, PG 64-16 CR
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byDave Last name of sampler or witnessed byLockett
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationD77396 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMercer Fraser Company, Willow Creek Plant Transportation Laboratory (TL) Number002139
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-06-S1 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-16-15
DIME Test ID: 2018-05-16-15-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2018-08-30

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Terry McCormick
Date of test: 06/01/2018
Specimen Treatment: Treated
Average Dry Tensile Strength: 136 psi
Average Wet Tensile Strength: 119 psi
Tensile Strength Ratio: 87
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2018