Summary for Test 2018-05-11-14-7

Test performed: AASHTO T210-15

Project Information

Project IdentifiersProject ID: 211705
DEA: 024G3804
EFIS: 0214000006
DIST-CO-RTE-PM02-TRI-299-0.0/8.3
Award Date11/30/2016
Closeout Date01/02/2019
Work DescriptionPLACE RUBBERIZED HOT MIX ASPHALT, GUARDRAIL, AND SOME DRAINAGE
Location DescriptionTRINITY COUNTY AT AND NEAR SALYER FROM HUMBOLDT COUNTY LINE TO 0.6 MILE EAST OF GRAY CREEK ROAD
QA Service Level1 (Verified on 10/25/2017)

Sample Information

Sample Taken Date05/11/2018 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2018
Sample typeVerification A brief description of the sampleSized Untreated Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byDave Last name of sampler or witnessed byLockett
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationD77362 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameMercer Fraser Company, Willow Creek Plant Transportation Laboratory (TL) Number002135
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-06-S1 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-12-0007::WILLOW CREEK
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample17-1006.112G
The plant numberUnknown A detailed description of where the material sample was collectedLab-batched from untreated stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 18-06-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-11-14
DIME Test ID: 2018-05-11-14-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2018-08-30

Test Results


Which test procedure(s) is/are used?: Procedure A and Procedure B
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 06/18/2018
Was strict temperature control maintained?: Yes
What type of water was used?: Distilled
Durability Index (coarse): 76
Durability Index (fine): 69
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/30/2018