Summary for Test 2018-07-20-12-3

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 211712
DEA: 07305204
EFIS: 0714000092
DIST-CO-RTE-PM07-VEN-33-15.7
Award Date11/28/2016
Closeout Date10/06/2022
Work DescriptionCONSTRUCT SOIL NAIL WALL AND ROCK SLOPE PROTECTION.
Location DescriptionVENTURA COUNTY NEAR OJAI AT 0.1 MILE SOUTH OF NORTH FORK MATILIJA CREEK BRIDGE
QA Service Level1 (Verified on 09/12/2016)

Sample Information

Sample Taken Date07/20/2018 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/25/2018
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed bypateleon Last name of sampler or witnessed byRivera
Title of samplerASR Telephone number of sampler805 375 9239
Laboratory sample identification984 628 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Number106628
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierna
Structure namena

Material Information

Material TypeConcrete The concrete mix design number3f36l001
The truck number from where the sample was collectedna The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleramussen
A detailed description of where the material sample was collectedna Where the material sample would have been placed if not sampledna
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-07-20-12
DIME Test ID: 2018-07-20-12-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-08-24

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 08/17/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 124900 lb
Maximum load on cylinder 2: 131630 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 4373.2 psi
Compressive strength of cylinder 2: 4625.1 psi
Compressive strength (to nearest 10 psi): 4500 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2018