Test 2018-05-15-36-6 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 212679
DEA: 023E7204
EFIS: 0200020154
DIST-CO-RTE-PM02-TEH-36-42.1/46.0
Work DescriptionCOLD PLANING, PAVING, MINOR CONCRETE, ELECTRICAL AND STRIPING WORK.
Location DescriptionTEHAMA COUNTY IN AND NEAR RED BLUFF FROM EAST SAND SLOUGH BRIDGE TO 0.6 MILE EAST OF STICE ROAD
Sample Information
Sample Taken Date5/15/2018 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/15/2018
Sample typeVerification A brief description of the sample3/4-inch RHMA-G, PG 64-16 CR
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byAllegretto
Title of samplerUnknown Laboratory sample identificationD77389
The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number847540
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-08-S1 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot numberNot set
Sublot numberNot set JMF Verification ID JMF3513-2018-26
Test Details
DIME Sample ID: 2018-05-15-36
DIME Test ID: 2018-05-15-36-6
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2018-08-06
Test Results

Input Type: Calculated
Tester's full name: Dennis Hickey
Date of test: 06/02/2018
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:no data
Impression at specified number of passes average:no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A):no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B):no data
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A):no data
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B):no data
Stripping Inflection Point (Wheel A):>25000
Stripping Inflection Point (Wheel B):no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/06/2018