Summary for Test 2018-05-21-2-1
Test performed: CONCLP 3-16Project Information
Project Identifiers | Project ID: 212011 DEA: 07252624 EFIS: 0700021272 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-R45.4/R61.2 |
Award Date | 04/17/2017 |
Closeout Date | 01/25/2021 |
Work Description | REHABILITATE CONCRETE PAVEMENT. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES AND AT CASTAIC FROM 0.2 MILE SOUTH OF ROUTE 14/5 SEPARATION TO 0.7 MILE NORTH OF PALOMAS WASH BRIDGE |
QA Service Level | 1 (Verified on 05/03/2017) |
Sample Information
Sample Taken Date | 05/21/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/21/2018 |
Sample type | Quality Control | A brief description of the sample | 1 gallon can |
The quantity of what the sample constitutes | 80 drums | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Nunes |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Kwik bond and Reichhold | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Polyester | Mfg. Lot Number(s) | 1119491 |
---|---|---|---|
Batch number | 1119491 | Mix number | 1119491 |
Test Details
DIME Sample ID: 2018-05-21-2
DIME Test ID: 2018-05-21-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-07-27
Test Results
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 07/27/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 102
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 60
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2960
Styrene ASTM D 2369 40% to 50 %: 46
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 733
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.1
General comments (publicly viewable) (Max 1000 characters): accepted suppliers results
Test was verified on 7/27/2018 ✔