Test 2018-05-21-2-1 (CONCLP 3-16) Summary

Project Information
Project IdentifiersProject ID: 212011
DEA: 07252624
EFIS: 0700021272
DIST-CO-RTE-PM07-LA-5-R45.4/R61.2
Work DescriptionREHABILITATE CONCRETE PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AND AT CASTAIC FROM 0.2 MILE SOUTH OF ROUTE 14/5 SEPARATION TO 0.7 MILE NORTH OF PALOMAS WASH BRIDGE
Sample Information
Sample Taken Date5/21/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/21/2018
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes80 drums From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypePolyester Mfg. Lot Number(s)1119491
Batch number1119491 Mix number1119491
Test Details
DIME Sample ID: 2018-05-21-2
DIME Test ID: 2018-05-21-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-07-27
Test Results

Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 07/27/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 102
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 60
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2960
Styrene ASTM D 2369 40% to 50 %: 46
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 733
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.1
General comments (publicly viewable) (Max 1000 characters): accepted suppliers results

Test was verified on 07/27/2018