Summary for Test 2018-06-13-2-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 213051
DEA: 060U9804
EFIS: 0616000182
DIST-CO-RTE-PM06-FRE-5-Var
Award Date03/06/2018
Closeout Date12/07/2018
Work DescriptionCONCRETE POLYESTER OVERLAY AND CONSTRUCT APPROACH SLABS.
Location DescriptionFRESNO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/04/2018)

Sample Information

Sample Taken Date06/13/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/13/2018
Sample typeQuality Control A brief description of the sample1 gallon can
The quantity of what the sample constitutes2 tankers From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKwik bond and Reichhold Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1124952
Batch number1124952 Mix number1124952

Test Details

DIME Sample ID: 2018-06-13-2
DIME Test ID: 2018-06-13-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-07-27

Test Results


Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 07/27/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 106
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 60.4
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3068
Styrene ASTM D 2369 40% to 50 %: 46.1
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 780
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.1
General comments (publicly viewable) (Max 1000 characters): accepted suppliers results