Summary for Test 2018-07-06-7-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 213032
DEA: 101G3304
EFIS: 1016000157
DIST-CO-RTE-PM10-MER-5,152-Var
Award Date03/13/2018
Closeout Date12/18/2018
Work DescriptionREPLACE JOINT SEALS, APPROACH SLABS, POLYESTER CONCRETE OVERLAY.
Location DescriptionMERCED COUNTY AT VARIOUS LOCATIONS.
QA Service Level1 (Verified on 04/24/2018)

Sample Information

Sample Taken Date07/06/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/06/2018
Sample typeQuality Assurance A brief description of the samplepolyester
The quantity of what the sample constitutes80 drums From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameKBP Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)0001129648
Batch number0001129648 Mix number3326

Test Details

DIME Sample ID: 2018-07-06-7
DIME Test ID: 2018-07-06-7-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2018-07-27

Test Results


Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 07/27/2018
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 105
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 64.7
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 3017
Styrene ASTM D 2369 40% to 50 %: 45.6
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 799
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.1
General comments (publicly viewable) (Max 1000 characters): accepted suppliers results

Test was verified on 7/27/2018