Summary for Test 2018-07-18-20-1
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 213153 DEA: 044S7804 EFIS: 0400020145 |
---|---|
DIST-CO-RTE-PM | 04-MRN-1-24.7 |
Award Date | 04/26/2018 |
Closeout Date | 10/17/2019 |
Work Description | REPLACE EXISTING CULVERTS WITH 36' REINFORCED CONCRETE SLAB BRIDGE. |
Location Description | MARIN COUNTY NEAR OLEMA AT 1.8 MILES SOUTH OF SIR FRANCIS DRAKE BOULEVARD |
QA Service Level | 1 (Verified on 06/12/2018) |
Sample Information
Sample Taken Date | 07/18/2018 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2018 |
Sample type | Quality Assurance | A brief description of the sample | A615 Grade 75 Threaded Bar |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Jade-Sterling, Nelsen Steel, Steel Dynamics | Transportation Laboratory (TL) Number | C74452 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | DS9301818 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | 10 |
Nut Specification for Threaded Bar | unknown | System Manufacturer | Unknown |
Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
Coating Standards | Uncoated | Bar Heat Number(s) | A162614 |
Nut Heat Number(s) | 8290416 | Bar Lot Number | Unknown |
Nut Lot Number | 3947 | Coupler Heat Number(s) | A163593 |
Coupler Grade | 75 |
Test Details
DIME Sample ID: 2018-07-18-20
DIME Test ID: 2018-07-18-20-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-08-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/24/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | #10 Bar Heat #A162614, Nut Heat #8290416, | S4301818 | 1.27 | 109004 | 84409 | 0 | Nut Stripped | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Stripped
Test Graph
Source: Partner Data Point FileTest was verified on 7/25/2018 ✔