Summary for Test 2017-05-15-14-10

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 211954
DEA: 022H4804
EFIS: 0216000106
DIST-CO-RTE-PM02-TRI-36-R3.5/R9.2
Award Date02/27/2017
Closeout Date04/02/2021
Work DescriptionCOLD IN-PLACE RECYCLE WITH HOT MIX ASPHALT OVERLAY AND GUARDRAIL
Location DescriptionTRINITY COUNTY NEAR MAD RIVER FROM 0.1 MILE EAST OF MAD RIVER ROAD TO 0.1 MILE WEST OF SOUTH FORK MOUNTAIN ROAD
QA Service Level1 (Verified on 07/27/2017)

Sample Information

Sample Taken Date05/15/2017 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/15/2017
Sample typeVerification A brief description of the sample1/2-inch Type A Untreated Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJoseph Last name of sampler or witnessed bySturges
Title of samplerPEI Tech Telephone number of samplerUnknown
Laboratory sample identificationD76928F Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTullis, Northstate Asphalt, Redding, CA Transportation Laboratory (TL) Number851342
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sample1/2-inch Type A Untreated Virgin Aggregate The fabricator/manufacturer designation for the sampleL170303
The plant numberUnknown A detailed description of where the material sample was collectedStockpiles at the Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 17-05-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2017-05-15-14
DIME Test ID: 2017-05-15-14-10
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2018-07-10

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: NRML-R
Date of test: 05/15/2017
Weighted percentage of particles (by mass) that were flat and elongated: 5 %
Weighted percentage of particles (by mass) that were not flat and elongated: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/10/2018