Test 2018-03-21-14-5 (ASTM C29-09) Summary

Project Information
Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
Sample Information
Sample Taken Date3/21/2018 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/29/2018
Sample typeAcceptance A brief description of the sampleLightweight fine agg
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byJohn Last name of sampler or witnessed byDong
Title of samplerUnknown Laboratory sample identification18-0047
The fabricator/manufacturer/facility nameAssociated Signal Hill Transportation Laboratory (TL) NumberC914206B
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)NA
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2018-03-21-14
DIME Test ID: 2018-03-21-14-5
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM C29-09: Standard Test Method for Bulk Density ("Unit Weight") and Voids in Aggregate
Test Release Date: 2018-07-03
Test Results

Type of bulk density to calculate: dry - using F factor
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 06/22/2018
Mass of aggregate + the measure: 27.4 lb
Mass of water + plate glass + measure: no data
Mass of plate glass + measure: 10.7 lb
Mass of Measure: no data
Factor for measure: 3.994 ft^-3
Dry Bulk Density:67 pcf
Method of compaction:rodding
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/03/2018