Summary for Test 2018-06-26-8-5
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 213267 DEA: 04013584 EFIS: 0416000289 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-8.0/8.3,0.9/1.4 |
Award Date | 03/29/2018 |
Closeout Date | 12/30/2019 |
Work Description | Pier Retention |
Location Description | In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
QA Service Level | 1 (Verified on 05/01/2018) |
Sample Information
Sample Taken Date | 06/26/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/28/2018 |
Sample type | Quality Assurance | A brief description of the sample | Epoxy Coated Rebar |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | D | Last name of sampler or witnessed by | Gray |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Fletcher Coating Co | Transportation Laboratory (TL) Number | C943269 C943271 C943273 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S3208718 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4076971, 4076126, 4075222 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | Rebar Coating Specification | ASTM A934 | |
Rebar Size (#) | 5, 6, 10 | Rebar Coating Color | Purple |
Rebar Manufacturer | CMC Rebar | Rebar Coater | Fletcher Coating Company |
Rebar Powder Manufacturer | Unknown | Release Number | 725-735 |
Quality Assurance Code | A93418F20R2S18A26, A93418F20R4S18D10 |
Test Details
DIME Sample ID: 2018-06-26-8
DIME Test ID: 2018-06-26-8-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-07-09
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 06/29/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 12 mils
Bar # for First Bar: 10
Bar # for Second Bar: 10
First Bar Side 1 mean value: 9.6
First Bar Side 2 mean value: 9.57
Second Bar Side 1 mean value: 9.59
Second Bar Side 2 mean value: 9.34
First Bar Mean: 9.59
Second Bar Mean: 9.47
Total mean value: 9.53
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/2/2018 ✔