Test 2018-06-25-3-2 (ASTM A722-15) Summary

Project Information
Project IdentifiersProject ID: 212354
DEA: 044K8504
EFIS: 0417000378
DIST-CO-RTE-PM04-MRN-1-22.8
Work DescriptionGiacomini Creek Bridge, Construct sheet pile wall, replace culvert
Location DescriptionROUTE 1, AT POSTMILE 22.8, NEAR BOLINAS, AT 0.52 MILES NORTH OF HORSESHOE HILL RD., MARIN COUNTY SLIPOUT, CONSTRUCT SOLDIER PILE WALL
Sample Information
Sample Taken Date6/25/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/25/2018
Sample typeQuality Assurance A brief description of the sample1 in ASTM A722
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byCarolina Last name of sampler or witnessed byMargarito
Title of samplerMETS Rep Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) NumberC647237
Inspector Lot Number from the Transportation Laboratory (TL) FormL73-010-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size8
Nut Specification for Threaded BarASTM A 29 System ManufacturerWilliams Form Eng
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)100884585
Nut Heat Number(s)NF15203286, 498335 Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)Unknown
Coupler GradeUnknown
Test Details
DIME Sample ID: 2018-06-25-3
DIME Test ID: 2018-06-25-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-07-03
Test Results

Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/26/2018
UTM: 400KIP
Temperature:72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 Williams 1\" Threaded Bar & Nut Bar #100884585, Nut #26D9D0.85166545138930100A722 Bar & nutFred

General comments (publicly viewable) (Max 1000 characters): A722 Bar & nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 06/26/2018