Summary for Test 2018-06-12-9-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date06/12/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/19/2018
Sample typeQuality Assurance A brief description of the sampleA490 Bolt assy
The quantity of what the sample constitutes7 From where was the sample collectedManufacturer
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSt Louis Screw Bolt Transportation Laboratory (TL) NumberC940067
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-077-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0102468
Heat Number(s) Nut Mfg. Lot Number(s)28043-178004
Washer Mfg. Lot Number(s)307768 Bolt SpecificationA490
Bolt Length(s)3.5 Nut SpecificationA563
Washer SpecificationF436 FinishPlain
Diameter/Size1 Bolt Mfg. Lot Number041547
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2018-06-12-9
DIME Test ID: 2018-06-12-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-06-29

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/20/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11B0415471\"97828435.210A490 BoltBrian

General comments (publicly viewable) (Max 1000 characters): A490 Bolt
Test Graph
Source: Partner Data Point File

Test was verified on 6/22/2018