Sample Information
Sample Taken Date6/12/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/19/2018
Sample typeQuality Assurance A brief description of the sampleA490 Bolt assy
The quantity of what the sample constitutes7 From where was the sample collectedManufacturer
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameSt Louis Screw Bolt Transportation Laboratory (TL) NumberC940067
Inspector Lot Number from the Transportation Laboratory (TL) FormL115-077-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0102468
Heat Number(s) Nut Mfg. Lot Number(s)28043-178004
Washer Mfg. Lot Number(s)307768 Bolt SpecificationA490
Bolt Length(s)3.5 Nut SpecificationA563
Washer SpecificationF436 FinishPlain
Diameter/Size1 Bolt Mfg. Lot Number041547
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2018-06-12-9
DIME Test ID: 2018-06-12-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-06-29
Test Results

Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/20/2018
UTM:400KIP
Temperature:no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11B0415471\"97828435.210A490 BoltBrian

General comments (publicly viewable) (Max 1000 characters): A490 Bolt
Test Graph
Source: Partner Data Point File