Summary for Test 2018-06-11-8-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212706 DEA: 051J4004 EFIS: 0517000095 |
---|---|
DIST-CO-RTE-PM | 05-SCR,SCR-9-11.0, 11.00 |
Award Date | 09/06/2017 |
Closeout Date | 09/20/2022 |
Work Description | Repair Slipout damage by constructing sidehill viaduct |
Location Description | Not set |
QA Service Level | 1 (Verified on 09/18/2017) |
Sample Information
Sample Taken Date | 06/11/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2018 |
Sample type | Quality Assurance | A brief description of the sample | Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | K | Last name of sampler or witnessed by | Nowak |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dextra America Nucor | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dextra America | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 8, 9 | Coupler Model | NA |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 4329,3801, 3715 | Rebar Heat Number(s) | Pl17110058, SE17101154 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-06-11-8
DIME Test ID: 2018-06-11-8-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-06-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/18/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #9/29mm | 1 | 0 | 91604 | 91604 | Ok Necking | Brian |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 6/18/2018 ✔