Summary for Test 2018-05-15-5-2

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 211513
DEA: 120M4904
EFIS: 1212000090
DIST-CO-RTE-PM12-ORA-5-1.2/2.2
Award Date09/20/2016
Closeout Date01/09/2020
Work DescriptionWIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS.
Location DescriptionORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING
QA Service Level1 (Verified on 11/03/2016)

Sample Information

Sample Taken Date05/15/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/25/2018
Sample typeAcceptance A brief description of the sampleA325 Fastener Assembly
The quantity of what the sample constitutes20 From where was the sample collectedSource
First name of sampler or witnessed byPrakash Last name of sampler or witnessed byPatel
Title of sampler Telephone number of sampler5626654686
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSLSB-IL Transportation Laboratory (TL) Number102
Inspector Lot Number from the Transportation Laboratory (TL) FormL1101018 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM A325
Bolt Length(s)3" Nut SpecificationA563
Washer SpecificationF436 FinishMech. Galv
Diameter/Size7/8" Bolt Mfg. Lot Number
Rocap Test Requirement(s)No Lubricant Requirements(s)No

Test Details

DIME Sample ID: 2018-05-15-5
DIME Test ID: 2018-05-15-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-06-13

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 06/01/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11ABM05897/8\"40981182.310Slipped outBrian

General comments (publicly viewable) (Max 1000 characters): Slipped out
Test Graph
Source: Partner Data Point File

Test was verified on 6/6/2018