Test 2018-04-20-6-1 (ASTM C39-10) Summary

Project Information
Project IdentifiersProject ID: 209694
DEA: 080J0704
EFIS: 0800000282
DIST-CO-RTE-PM08-SBD-215-0.6/1.7
Work Description(Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location DescriptionGrade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
Sample Information
Sample Taken Date4/20/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/16/2018
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTim Last name of sampler or witnessed byFlores
Title of samplerSR Laboratory sample identification975
The fabricator/manufacturer/facility nameROBERTSON CORONA Transportation Laboratory (TL) Number0420
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierBARTON ROAD INTERCHANE ABUTMENT 4 RGHT BR STAGE 1
Structure nameBARTON ROAD INTERCHANE ABUTMENT 4 RGHT BR STAGE 1
Material Information
Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collected1988 The batch plant ticket number from where the sample was collected3595422
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown
Test Details
DIME Sample ID: 2018-04-20-6
DIME Test ID: 2018-04-20-6-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-05-30
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Minh Pham
Date of test: 05/18/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 137120 lb
Maximum load on cylinder 2: 134590 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 4881.5 psi
Compressive strength of cylinder 2: 4791.4 psi
Compressive strength (to nearest 10 psi):4840 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/23/2018