Summary for Test 2018-05-17-12-4

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout DateNot set
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date05/17/2018 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/21/2018
Sample typeQuality Assurance A brief description of the sample4 Epoxy coated 4 Plain soil nails
The quantity of what the sample constitutes10000 feet From where was the sample collectedManufacturer
First name of sampler or witnessed byGreg Last name of sampler or witnessed byThompson
Title of samplerAssociate Steel Inspector Telephone number of sampler5103767155
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Engineering Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB904918 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size8
Nut Specification for Threaded BarNA System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)1002890429, 100890427
Nut Heat Number(s)Unknown Bar Lot NumberUnknown
Nut Lot Number8S3D Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-05-17-12
DIME Test ID: 2018-05-17-12-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-05-31

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/22/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
12#8 Williams Bar Ht #100890427Nut Heat #8S3DB9-049-180.79113161966530Nut TestFred

General comments (publicly viewable) (Max 1000 characters): Nut Test
Test Graph
Source: Partner Data Point File

Test was verified on 5/24/2018