Summary for Test 2018-05-14-7-3

Test performed: CTM 670-December 2013

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/14/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/14/2018
Sample typeAcceptance A brief description of the sampleErico Position Coupler
The quantity of what the sample constitutes8 From where was the sample collectedManufacturer
First name of sampler or witnessed byAnirudha Last name of sampler or witnessed byVaidya
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameNucor Erico Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelPosition Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)LA-834, LA-873, LA-905, LA-870 Rebar Heat Number(s)SE16103928, SE16104013
Rebar Size 2 11 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-05-14-7
DIME Test ID: 2018-05-14-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2018-07-12

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/22/2018
UTM: 400KIP
Temperature: 72 F
Halo ID: NA
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131008/25mm SLA-834, LA-87300.797571895846Necking OkBrian

General comments (publicly viewable) (Max 1000 characters): Necking Ok
Test Graph
Source: Partner Data Point File

Test was verified on 7/5/2018