Test 2018-05-14-18-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 212680
DEA: 024F5504
EFIS: 0213000005
DIST-CO-RTE-PM02-SIS-89-20.9 - 21.2
Work DescriptionBRIDGE REPLACEMENT WITH PRE-CAST I-GIRDER AND RECONSTRUCT HIGHWAY
Location DescriptionSISKIYOU COUNTY NEAR MCCLOUD FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF MUD CREEK BRIDGE
Sample Information
Sample Taken Date5/14/2018 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/14/2018
Sample typeVerification A brief description of the sampleCold Feed
The quantity of what the sample constitutesJMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byAllegretto
Title of samplerPEI Laboratory sample identificationD77366A
The fabricator/manufacturer/facility nameTullis, Northstate Asphalt, Redding, CA Transportation Laboratory (TL) Number853535
Inspector Lot Number from the Transportation Laboratory (TL) FormJMF Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-45-0057
The fabricator's/manufacturer's product name for the sampleCold Feed The fabricator/manufacturer designation for the sampleL170303
The plant numberUnknown A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberJMF 17-05-R1 Lot numberNot set
Sublot numberNot set JMF Verification ID JMF3513-2018-20
Test Details
DIME Sample ID: 2018-05-14-18
DIME Test ID: 2018-05-14-18-1
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-07-10
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 05/15/2018
Total mass of material in the sample: 3392.7 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 194 grams
Cumulative mass retained on the 3/8 in. sieve: 607 grams
Mass retained on the 1/4 in. sieve: 1161 grams
Cumulative mass retained on the #4 sieve: 1465 grams
Total sample mass passing the #4 sieve: 1927.7 grams
Total mass of fine material in the sample: 515.9 grams
Cumulative mass retained on the #8 sieve: 184.9 grams
Cumulative mass retained on the #16 sieve: 298.2 grams
Cumulative mass retained on the #30 sieve: 363.2 grams
Cumulative mass retained on the #50 sieve: 408.1 grams
Cumulative mass retained on the #100 sieve: 437.6 grams
Cumulative mass retained on the #200 sieve: 455.5 grams
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:94 %
Cumulative percent passing the 3/8 in. sieve:82 %
Cumulative percent passing the 1/4 in. sieve:66 %
Cumulative percent passing the #4 sieve:57 %
Cumulative percent passing the #8 sieve:37 %
Cumulative percent passing the #16 sieve:24 %
Cumulative percent passing the #30 sieve:17 %
Cumulative percent passing the #50 sieve:12 %
Cumulative percent passing the #100 sieve:9 %
Cumulative percent passing the #200 sieve:6.7 %
General comments (publicly viewable) (Max 1000 characters): JMF 17-05-R1 Cold Feed

Test was verified on 07/10/2018