Summary for Test 2018-05-14-8-5
Test performed: CTM 670-December 2013Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/14/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2018 |
Sample type | Acceptance | A brief description of the sample | Erico Standard Coupler |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anirudha | Last name of sampler or witnessed by | Vaidya |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Erico Lenton | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Erico | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 4, 8 | Coupler Model | Standard Coupler |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | LA-846, LA-836, LA-873 | Rebar Heat Number(s) | 283716, SE16103928 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-05-14-8
DIME Test ID: 2018-05-14-8-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2018-05-28
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/18/2018
UTM: 400KIP
Temperature: 72 F
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 10K-1 | 100 | #8/25mm | LA836, LA-873 | 0 | 0.79 | 75263 | 95270 | 10K Break | Fred |
General comments (publicly viewable) (Max 1000 characters): 10K Break
Test Graph
Source: Partner Data Point FileTest was verified on 5/21/2018 ✔