Summary for Test 2018-05-09-8-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210631 DEA: 040J2904 EFIS: 0413000429 |
---|---|
DIST-CO-RTE-PM | 04-ALA-61-18.5 |
Award Date | 06/02/2017 |
Closeout Date | 02/22/2019 |
Work Description | SPOT BLAST CLEAN, PAINT STEEL ELEMENTS, AND PERFORM WORK IN BUILDING. |
Location Description | ALAMEDA COUNTY IN ALAMEDA AT SAN LEANDRO BAY BRIDGE AND AT SAN LEANDRO BAY BIKE BRIDGE |
QA Service Level | 1 (Verified on 04/07/2017) |
Sample Information
Sample Taken Date | 05/09/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Ulmer Industries | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-078-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0101452 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 27492-75069718 | |
Washer Mfg. Lot Number(s) | 305662 | Bolt Specification | F3125, A325 |
Bolt Length(s) | 1.75 | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 5/8 x 1.75 | Bolt Mfg. Lot Number | BG0965 |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-05-09-8
DIME Test ID: 2018-05-09-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brain
Date of test: 05/16/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 27492-75069718 | 5/8\" | 34640 | 154.09 | Nut Proof Load | Brain |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 5/16/2018 ✔