Summary for Test 2018-05-01-2-1

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 211778
DEA: 04235654
EFIS: 0400000680
DIST-CO-RTE-PM04-SM-101,114-1.3/2.5,5.0/5.3
Award Date02/10/2017
Closeout Date01/08/2020
Work DescriptionRECONSTRUCT INTERCHANGE
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATIONS ON ROUTE 101 FROM 0.4 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.6 MILE SOUTH OF HENDERSON UNDERPASS AND ON ROUTE 114 FROM WILLOW ROAD SEPARATION TO NEWBRIDGE STREET
QA Service Level1 (Verified on 10/24/2016)

Sample Information

Sample Taken Date05/01/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/07/2018
Sample typeQuality Assurance A brief description of the sample.5 Prestressing Strand
The quantity of what the sample constitutes6 strand packs From where was the sample collectedOther
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Kie-Con Antioch Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-029-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsCurve S100001R
Reel/Coil/Pack Number(s)1 - S530809-3 2 - S530812-1 3 - S530810-3 4 - S530812-2 5 - S530811-3 6 - S530811-6 Number of Coils6
Group NumberUnknown Strand Diameter.5 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0531917 Mfg. Lot Number(s)SIPC180475
Manufacturer(s)SWPC

Test Details

DIME Sample ID: 2018-05-01-2
DIME Test ID: 2018-05-01-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-05-17

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 05/10/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0531917S530810-30.15423763885628.11.89Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 5/10/2018