Summary for Test 2018-05-02-2-1

Test performed: ASTM A370-15

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date05/02/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/07/2018
Sample typeQuality Assurance A brief description of the sample2 Ductile Iron Casting
The quantity of what the sample constitutes2 From where was the sample collectedManufacturer
First name of sampler or witnessed byDebbie Last name of sampler or witnessed byOzuna
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDSI Farrar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)C298
Part Number (s)68 27 172 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar
Prestressing ManufacturerDSI

Test Details

DIME Sample ID: 2018-05-02-2
DIME Test ID: 2018-05-02-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2018-05-17

Test Results


Number of Samples: 2
Input Type: Calculated
Tester's full name: Brian
Date of test: 05/09/2018
UTM: 67KIP
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1C2980.4960.1932630351096808.4Brian
2C2980.4960.1932631451106308.9Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 5/10/2018