Summary for Test 2018-04-23-5-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211982
DEA: 060K4604
EFIS: 0612000105
DIST-CO-RTE-PM06-KER-46,99-57.3/57.8,43.9/44.6
Award Date05/05/2017
Closeout Date10/17/2019
Work DescriptionREALIGN ROADWAY AND CONSTRUCT NEW BRIDGE.
Location DescriptionKERN COUNTY NEAR FAMOSO ON ROUTE 46 FROM 0.5 MILE WEST OF ROUTE 46/99 SEPARATION TO 0.1 MILE EAST OF ROUTE 46/99 SEPARATION AND ON ROUTE 99 FROM 0.4 MILE SOUTH OF ROUTE 46/99 SEPARATION TO 0.3 MILE NORTH OF ROUTE 46/99 SEPARATION
QA Service Level1 (Verified on 06/26/2017)

Sample Information

Sample Taken Date04/23/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/26/2018
Sample typeQuality Assurance A brief description of the sampleFlash welded hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9167993391
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Tracy Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-140-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4073639
Hoop Manufacturer Lot Number(s)1, 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop4' 5" 4' 2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Arizona
Welding CompanyCMC Rebar (Tracy) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-04-23-5
DIME Test ID: 2018-04-23-5-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-05-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/27/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#8/25mm 4-50.796406081090Bar Broke in WeldFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke in Weld; NO Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/27/2018