Summary for Test 2018-04-23-5-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211982 DEA: 060K4604 EFIS: 0612000105 |
---|---|
DIST-CO-RTE-PM | 06-KER-46,99-57.3/57.8,43.9/44.6 |
Award Date | 05/05/2017 |
Closeout Date | 10/17/2019 |
Work Description | REALIGN ROADWAY AND CONSTRUCT NEW BRIDGE. |
Location Description | KERN COUNTY NEAR FAMOSO ON ROUTE 46 FROM 0.5 MILE WEST OF ROUTE 46/99 SEPARATION TO 0.1 MILE EAST OF ROUTE 46/99 SEPARATION AND ON ROUTE 99 FROM 0.4 MILE SOUTH OF ROUTE 46/99 SEPARATION TO 0.3 MILE NORTH OF ROUTE 46/99 SEPARATION |
QA Service Level | 1 (Verified on 06/26/2017) |
Sample Information
Sample Taken Date | 04/23/2018 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/26/2018 |
Sample type | Quality Assurance | A brief description of the sample | Flash welded hoops |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9167993391 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Tracy | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-140-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4073639 |
Hoop Manufacturer Lot Number(s) | 1, 2 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 8 |
Diameter of Hoop | 4' 5" 4' 2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
Welding Company | CMC Rebar (Tracy) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-04-23-5
DIME Test ID: 2018-04-23-5-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-05-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/27/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #8/25mm 4-5 | 0.79 | 73570 | 93130 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/27/2018 ✔