Summary for Test 2014-02-20-6529-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 8127
DEA: 080N5904
EFIS: 0800000533
DIST-CO-RTE-PM08-SBD-40-R85.2
Award Date02/07/2013
Closeout Date05/11/2015
Work DescriptionCONSTRUCT PC/PS BULB-TEE GIRDER BRIDGE
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT VAN WINKLE WASH BRIDGE
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date02/20/2014 Sample Unique Key6529
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/28/2014
Sample typeVerification A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes6 cylinders From where was the sample collectedSource
First name of sampler or witnessed byLarry Last name of sampler or witnessed bycaltrans
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameHigh Grade-08 Oro grand Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeConcrete The concrete mix design numberSITI72SK
The truck number from where the sample was collectedNot set The batch plant ticket number from where the sample was collected81725
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collectedDeck Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2014-02-20-6529
DIME Test ID: 2014-02-20-6529-1
Testing Lab: Twining, Incorporated - San Bernardino
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-03-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Andrew Solis
Date of test: 03/21/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 140500 lb
Maximum load on cylinder 2: 141000 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4952.4 psi
Compressive strength of cylinder 2: 4970.0 psi
Compressive strength (to nearest 10 psi): 4960 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/21/2014