Test 2018-04-19-1-3 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
Sample Information
Sample Taken Date4/19/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/20/2018
Sample typeQuality Assurance A brief description of the sampleA490 Bolts
The quantity of what the sample constitutes3 lots From where was the sample collectedSource
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerQA Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameSLSB Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL53-018-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0100659, TT0100660, TT0100661
Heat Number(s) Nut Mfg. Lot Number(s)27479-178004
Washer Mfg. Lot Number(s)307768 Bolt SpecificationF3125, A490
Bolt Length(s)2.75", 3", 3.250 Nut SpecificationA563
Washer SpecificationF436 FinishBlack
Diameter/Size1" Bolt Mfg. Lot Number752410, 043097, 041847
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2018-04-19-1
DIME Test ID: 2018-04-19-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-08
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/25/2018
UTM:400KIP
Temperature:72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11B27479-1780041-8 HEX109200485.75Nut ProofFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point File

Test was verified on 05/01/2018