Summary for Test 2018-04-16-1-2

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date04/16/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/17/2018
Sample typeVerification A brief description of the samplestock hardware
The quantity of what the sample constitutesvaries From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byFlygare
Title of samplerCA METS QA Inspector Telephone number of sampler801-669-2984
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUIS Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormB76-071-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)none
Heat Number(s)10466920, 20339290, 20411200, 20433840, 75061539, 166333, 10466960, 6214130803, 6214279005, 416992, 511580, 417390, 420891 Nut Mfg. Lot Number(s)23501-166333, 17-04-005, 23750-6214130803, 25480,
Washer Mfg. Lot Number(s)D1703, D1214, D2017, D0022 Bolt SpecificationA325
Bolt Length(s)1 1/2", 2 1/2", 2 1/4", 3 1/2", 4 1/2" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMG
Diameter/Sizevaries Bolt Mfg. Lot NumberBM0527, M4514, BM0329, BM0447, M4450
Rocap Test Requirement(s)none Lubricant Requirements(s)none

Test Details

DIME Sample ID: 2018-04-16-1
DIME Test ID: 2018-04-16-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-05-02

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/20/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
13ABM03295/8\"30586136.110A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 4/25/2018