Test 2018-04-18-1-4 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 210808
DEA: 020E0904
EFIS: 0200000016
DIST-CO-RTE-PM02-SHA-5-R29.3/R31.1,R45.0/R45.8
Work DescriptionREPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT
Location DescriptionIN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE.
Sample Information
Sample Taken Date4/18/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing4/18/2018
Sample typeRetest A brief description of the sample Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byGlen Last name of sampler or witnessed byLawson
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC340590
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-018-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingRetest
Service or UltimateService Material Standard CodeASTM A955
Material Grade75 Rebar ManufacturerHarris Rebar
Coupler ManufacturerHarris Rebar Intermediate Assembler or FabricatorUnknown
Rebar Size8 Coupler ModelThreaded stainless Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s) M9P1 Rebar Heat Number(s)34R1
Rebar Size 2 Not set
Test Details
DIME Sample ID: 2018-04-18-1
DIME Test ID: 2018-04-18-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-04-30
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/19/2018
UTM: 400KIP
Halo ID: Small
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
14C05#8/25mm0.79079023100030Service SpliceBrian

General comments (publicly viewable) (Max 250 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 04/23/2018