Summary for Test 2018-04-10-1-1
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 210828 DEA: 07290704 EFIS: 0712000076 |
---|---|
DIST-CO-RTE-PM | 07-LA-47-0.9/2.0 |
Award Date | 04/06/2016 |
Closeout Date | 06/25/2019 |
Work Description | RESTORE BRIDGE SEISMIC. |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/03/2016) |
Sample Information
Sample Taken Date | 04/10/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/18/2018 |
Sample type | Quality Assurance | A brief description of the sample | A449 Anchor Rods |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Cummings |
Title of sampler | QA Inspector | Telephone number of sampler | 916-718-7759 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CK Johnson INdustries | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S29-037-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 6214434108 | Nut Mfg. Lot Number(s) | 26729 |
Washer Mfg. Lot Number(s) | 0817-609 | Bolt Specification | A449 |
Bolt Length(s) | 20-1/4" , 18-3/4" | Nut Specification | A563 |
Washer Specification | F436 | Finish | GALV. |
Diameter/Size | 1-1/4 | Bolt Mfg. Lot Number | 166399 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue dye |
Test Details
DIME Sample ID: 2018-04-10-1
DIME Test ID: 2018-04-10-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-04-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2018
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | A449 1.250 x 18.75\" Stud w / Nut | 0.969 | 120745 | 537 | 124608 | 122315 | 118523 | A449 Stud & Nut |
General comments (publicly viewable) (Max 1000 characters): A449 Stud & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 4/23/2018 ✔