Summary for Test 2018-04-12-5-2
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 212795 DEA: 05937704 EFIS: 0514901244 Permit Numbers: 05176UB0132 |
---|---|
DIST-CO-RTE-PM | 05-MON-68-4.04 |
Award Date | 09/06/2017 |
Closeout Date | 05/24/2019 |
Work Description | Install a water pipeline bridge including a 36 inch diameter steel casing |
Location Description | County of Monterey |
QA Service Level | 1 (Verified on 09/25/2017) |
Sample Information
Sample Taken Date | 04/12/2018 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2018 |
Sample type | Quality Assurance | A brief description of the sample | A449 Threaded rod |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | QAI | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | C740748 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-124-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | A175837, B46227, 6214434108 | Nut Mfg. Lot Number(s) | 26728-6214434108 |
Washer Mfg. Lot Number(s) | 0218-749 | Bolt Specification | A449 |
Bolt Length(s) | Unknown | Nut Specification | A563 |
Washer Specification | F436-1 | Finish | HDG |
Diameter/Size | 1-1/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-04-12-5
DIME Test ID: 2018-04-12-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-05-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/18/2018
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 1A | A449 1.250 x 60.5\" Althread Rod w / Nut | 0.969 | 132674 | 590 | 136919 | 123265 | 119444 | A449 Rod & Nut |
General comments (publicly viewable) (Max 1000 characters): A449 Rod & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 4/24/2018 ✔