Summary for Test 2018-03-07-7-1
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 212869 DEA: 060V1804 EFIS: 0617000169 |
---|---|
DIST-CO-RTE-PM | 06-KER,TUL-99,190-49.3/57.6;14.6/20.9 |
Award Date | 01/16/2018 |
Closeout Date | 10/23/2020 |
Work Description | COLD PLANE, REPAIR FAILED AC PVMT AND RESURFACE WITH RHMA-O(BWC). |
Location Description | KERN AND TULARE COUNTIES IN AND NEAR MCFARLAND ON ROUTE 99 FROM SHERWOOD AVENUE OVERCROSSING TO TULARE COUNTY LINE AND IN AND NEAR PORTERVILLE ON ROUTE 190 FROM 0.3 MILE WEST OF PROSPECT STREET TO 0.2 MILE WEST OF ROAD 284 |
QA Service Level | 1 (Verified on 12/19/2018) |
Sample Information
Sample Taken Date | 03/07/2018 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/16/2018 |
Sample type | Annual Source Testing | A brief description of the sample | 1 x 4 PCC Aggregate |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Ruiz |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 18-0024 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Porterville Rock | Transportation Laboratory (TL) Number | C980224A |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-54-0038::WILCOX MINE |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | Unknown | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-03-07-7
DIME Test ID: 2018-03-07-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2018-04-12
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 04/12/2018
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 5.6 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/12/2018 ✔