Summary for Test 2018-04-06-6-1

Test performed: ASTM A884-14

Project Information

Project IdentifiersProject ID: 212577
DEA: 11408704
EFIS: 1112000017
DIST-CO-RTE-PM11-SD-8-9.0/15.3
Award Date10/31/2017
Closeout Date12/09/2019
Work DescriptionSLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location DescriptionSAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
QA Service Level1 (Verified on 01/19/2018)

Sample Information

Sample Taken Date04/06/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/09/2018
Sample typeQuality Assurance A brief description of the sample1-1/4 A775 Dowels
The quantity of what the sample constitutes1900 Loose Dowels From where was the sample collectedFabricator
First name of sampler or witnessed byRob Last name of sampler or witnessed byRamos
Title of samplerQA Telephone number of sampler916-996-2658
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameDayton Superior Modesto Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormS08-010-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Dowels Dowel Metal Heat Number120200600, 1201000609, 1201000610
Dowel Epoxy Batch Number7T96025845 Dowel Coating SpecificationASTM A775
Dowel Size1.25 in Dowel Coating ColorGreen
Dowel ManufacturerNucor Dowel CoaterDayton Superior
Release Number1412609-1, 1402397-1 Quality Assurance CodeUnknown
Rebar Size (#)Unknown

Test Details

DIME Sample ID: 2018-04-06-6
DIME Test ID: 2018-04-06-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2018-04-18

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/10/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
First Bar Side 1 mean value: 15.21 mils
First Bar Side 2 mean value: 15.78 mils
Second Bar Side 1 mean value: 13.7 mils
Second Bar Side 2 mean value: 12.93 mils
First Bar Mean: 15.5 mils
Second Bar Mean: 13.32 mils
Total mean value: 14.41 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/11/2018