Summary for Test 2018-04-06-6-1
Test performed: ASTM A884-14Project Information
Project Identifiers | Project ID: 212577 DEA: 11408704 EFIS: 1112000017 |
---|---|
DIST-CO-RTE-PM | 11-SD-8-9.0/15.3 |
Award Date | 10/31/2017 |
Closeout Date | 12/09/2019 |
Work Description | SLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL. |
Location Description | SAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON |
QA Service Level | 1 (Verified on 01/19/2018) |
Sample Information
Sample Taken Date | 04/06/2018 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2018 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/4 A775 Dowels |
The quantity of what the sample constitutes | 1900 Loose Dowels | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Ramos |
Title of sampler | QA | Telephone number of sampler | 916-996-2658 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Dayton Superior Modesto | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S08-010-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Dowels | Dowel Metal Heat Number | 120200600, 1201000609, 1201000610 |
---|---|---|---|
Dowel Epoxy Batch Number | 7T96025845 | Dowel Coating Specification | ASTM A775 |
Dowel Size | 1.25 in | Dowel Coating Color | Green |
Dowel Manufacturer | Nucor | Dowel Coater | Dayton Superior |
Release Number | 1412609-1, 1402397-1 | Quality Assurance Code | Unknown |
Rebar Size (#) | Unknown |
Test Details
DIME Sample ID: 2018-04-06-6
DIME Test ID: 2018-04-06-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2018-04-18
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/10/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
First Bar Side 1 mean value: 15.21 mils
First Bar Side 2 mean value: 15.78 mils
Second Bar Side 1 mean value: 13.7 mils
Second Bar Side 2 mean value: 12.93 mils
First Bar Mean: 15.5 mils
Second Bar Mean: 13.32 mils
Total mean value: 14.41 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/11/2018 ✔