Summary for Test 2018-03-19-12-6

Test performed: ASTM D471-15a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/19/2018 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/26/2018
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameD S Brown Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0218165-A
Manufacturer(s)D S Brown Temperature70
Humidity50 CommentsUnknown
Joint Seal Size2.5

Test Details

DIME Sample ID: 2018-03-19-12
DIME Test ID: 2018-03-19-12-6
Testing Lab: CT HQ - Sacramento Chemistry Laboratory
Test Method: ASTM D471-15a: Standard Test Method for Rubber Property - Effect of Liquids
Test Release Date: 2018-04-09

Test Results


Input Type: Calculated
Tester's full name: Mariano Pontillas
Date of test: 04/02/2018
Oil Swell Percentage: 43 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/2/2018