Summary for Test 2018-03-20-8-3

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/20/2018 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/28/2018
Sample typeQuality Assurance A brief description of the sampleA325 HDG Rocap Assembiy
The quantity of what the sample constitutes5 From where was the sample collectedManufacturer
First name of sampler or witnessed byJason Last name of sampler or witnessed byWilliams
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameAmeron International Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)1373701
Heat Number(s) Nut Mfg. Lot Number(s)Unytite
Washer Mfg. Lot Number(s)305695 Bolt SpecificationA325
Bolt Length(s)5.5 Nut SpecificationA563
Washer SpecificationF436 FinishF2329
Diameter/Size1 Bolt Mfg. Lot Number761555
Rocap Test Requirement(s) Lubricant Requirements(s)Blue

Test Details

DIME Sample ID: 2018-03-20-8
DIME Test ID: 2018-03-20-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-04-06

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/29/2018
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A27136-1778951\"93357415.27Proof LoadFred

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Partner Data Point File

Test was verified on 3/30/2018