Test 2018-02-27-18-9 (AASHTO T210-15) Summary

Project Information
Project IdentifiersProject ID: 212679
DEA: 023E7204
EFIS: 0200020154
DIST-CO-RTE-PM02-TEH-36-42.1/46.0
Work DescriptionCOLD PLANING, PAVING, MINOR CONCRETE, ELECTRICAL AND STRIPING WORK.
Location DescriptionTEHAMA COUNTY IN AND NEAR RED BLUFF FROM EAST SAND SLOUGH BRIDGE TO 0.6 MILE EAST OF STICE ROAD
Sample Information
Sample Taken Date2/27/2018 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/27/2018
Sample typeVerification A brief description of the sampleVirgin 1/2-inch Type A Untreated
The quantity of what the sample constitutesJMF From where was the sample collectedManufacturer
First name of sampler or witnessed byCheryl Last name of sampler or witnessed byAbraham
Title of samplerUnknown Laboratory sample identificationD77292F
The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number852088
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedLab-batched from untreated stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set JMF Verification ID JMF3513-2018-19
Test Details
DIME Sample ID: 2018-02-27-18
DIME Test ID: 2018-02-27-18-9
Testing Lab: CT D02 - North Region Materials Lab
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2018-03-27
Test Results

Which test procedure(s) is/are used?: Procedure A and Procedure B
Input Type: Measured
Tester's full name: Valasek/Cruz
Date of test: 03/02/2018
Was strict temperature control maintained?: Yes
What type of water was used?: Distilled
Height of sediment column: 0.4 in
Clay reading: 4.7 in
Sand reading: 3.9 in
Durability Index (coarse):87
Durability Index (fine):83
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/27/2018