Summary for Test 2018-03-13-5-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 3807
DEA: 07121844
EFIS: 0700000117
DIST-CO-RTE-PM07-LA-5-42.8/47.3
Award Date12/06/2010
Closeout Date06/30/2021
Work DescriptionCONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 02/23/2012)

Sample Information

Sample Taken Date03/13/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/15/2018
Sample typeQuality Assurance A brief description of the sample7/8 x 4 HS Bolt
The quantity of what the sample constitutes50 From where was the sample collectedManufacturer
First name of sampler or witnessed byJeffrey Last name of sampler or witnessed bySulka
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSt Louis Screw and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL81-009-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0099214
Heat Number(s)10447770 Nut Mfg. Lot Number(s)26476-6214342202
Washer Mfg. Lot Number(s)D4413 Bolt SpecificationASTM A325
Bolt Length(s)4" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishGalvanized
Diameter/Size7/8 Bolt Mfg. Lot NumberM4581
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2018-03-13-5
DIME Test ID: 2018-03-13-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-03-27

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/19/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
14B0415257/8\"66378295.310A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 3/20/2018