Test 2018-03-05-4-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 209694
DEA: 080J0704
EFIS: 0800000282
DIST-CO-RTE-PM08-SBD-215-0.6/1.7
Work Description(Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location DescriptionGrade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
Sample Information
Sample Taken Date3/5/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/9/2018
Sample typeQuality Assurance A brief description of the sample8 - Flash Welded Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQAI Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL110 021-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)6502396002
Hoop Manufacturer Lot Number(s)Lot 1 and Lot 6 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop3'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerGerdau
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2018-03-05-4
DIME Test ID: 2018-03-05-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-03-19
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/09/2018
UTM:400KIP
Temperature:72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#8/25mm0.797373093330Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 03/12/2018