Test 2018-02-27-6-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 211076
DEA: 040K6914
EFIS: 0416000166
DIST-CO-RTE-PM04-SF-80-8.2/8.6
Work DescriptionInstall grease caps and repair pre-stress tendon
Location DescriptionIn SF at the eastern span of the SF-Oakland Bay Bridge
Sample Information
Sample Taken Date2/27/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing2/28/2018
Sample typeQuality Assurance A brief description of the sampleA352 HH Bolt
The quantity of what the sample constitutes1 lot From where was the sample collectedDistributor
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Laboratory sample identification
The fabricator/manufacturer/facility nameBay Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-009-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)1840-04
Heat Number(s)10088415 Nut Mfg. Lot Number(s)387398B
Washer Mfg. Lot Number(s)305068 Bolt SpecificationA325
Bolt Length(s)2.25" Nut SpecificationA563, Gr DH
Washer SpecificationA436 FinishHDG
Diameter/Size5/8" Bolt Mfg. Lot Number386693A
Rocap Test Requirement(s)Yes Lubricant Requirements(s)yes
Test Details
DIME Sample ID: 2018-02-27-6
DIME Test ID: 2018-02-27-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-03-09
Test Results

Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/02/2018
UTM:400KIP
Temperature:no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
16A386693A5/8\"31322139.310A325Brian

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 03/02/2018