Summary for Test 2018-02-15-1-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212795 DEA: 05937704 EFIS: 0514901244 Permit Numbers: 05176UB0132 |
---|---|
DIST-CO-RTE-PM | 05-MON-68-4.04 |
Award Date | 09/06/2017 |
Closeout Date | 05/24/2019 |
Work Description | Install a water pipeline bridge including a 36 inch diameter steel casing |
Location Description | County of Monterey |
QA Service Level | 1 (Verified on 09/25/2017) |
Sample Information
Sample Taken Date | 02/15/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2018 |
Sample type | Verification | A brief description of the sample | 3/4 x 7 A325 HDG bolt |
The quantity of what the sample constitutes | 9 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-034-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
---|---|---|---|
Heat Number(s) | 100884270 | Nut Mfg. Lot Number(s) | none |
Washer Mfg. Lot Number(s) | none | Bolt Specification | A325 |
Bolt Length(s) | 7" | Nut Specification | none |
Washer Specification | none | Finish | HDG |
Diameter/Size | 3/4" x 7" | Bolt Mfg. Lot Number | SLSB, G9036 |
Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2018-02-15-1
DIME Test ID: 2018-02-15-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-03-01
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/22/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | G9036 | 3/4\" | 47751 | 212.4 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 2/22/2018 ✔