Test 2017-11-01-38-3 (ASTM D36-14ε1) Summary

Project Information
Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date11/1/2017 Sample Unique Key38
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/1/2017
Sample typeVerification A brief description of the samplefor JMF verification
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byThinh Last name of sampler or witnessed byNguyen
Title of samplerUnknown Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameMustang Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplierUnknown
Performance GradeNot set Lot numberNot set
Sublot numberNot set JMF Verification ID JMF3513-2017-1
Test Details
DIME Sample ID: 2017-11-01-38
DIME Test ID: 2017-11-01-38-3
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2018-02-08
Test Results

ASTM Thermometer used?: C
Input Type: Calculated
Tester's full name: David Phong
Date of test: 02/08/2018
Softening Point Sample 1:130 C
Softening Point Sample 2:no data
Bath Liquid:freshly boiled distilled water
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 02/08/2018