Summary for Test 2018-01-30-2-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211784
DEA: 11085784
EFIS: 1100000064
DIST-CO-RTE-PM11-SD-163-4.1/4.9
Award Date06/16/2017
Closeout Date08/10/2021
Work DescriptionINTERCHANGE MODIFICATION AND OVERCROSSING WIDENING.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING
QA Service Level1 (Verified on 09/05/2017)

Sample Information

Sample Taken Date01/30/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/30/2018
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes120 From where was the sample collectedFabricator
First name of sampler or witnessed byLorenzo Last name of sampler or witnessed byGarcia
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)7
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop6'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar Manufacturer1
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2018-01-30-2
DIME Test ID: 2018-01-30-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-02-09

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 02/01/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
131#7/22mm0.65886098100Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 2/2/2018