Test 2018-01-19-2-1 (ASTM A775-07b-re14) Summary

Project Information
Project IdentifiersProject ID: 212577
DEA: 11408704
EFIS: 1112000017
DIST-CO-RTE-PM11-SD-8-9.0/15.3
Work DescriptionSLAB REPLACEMENT, COLD PLANE, GRIND PAVEMENT AND REPLACE GUARDRAIL.
Location DescriptionSAN DIEGO COUNTY FROM 0.6 MILE WEST OF LAKE MURRAY BOULEVARD OVERCROSSING IN SAN DIEGO TO JOHNSON AVENUE UNDERCROSSING IN EL CAJON
Sample Information
Sample Taken Date1/19/2018 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/23/2018
Sample typeAcceptance A brief description of the sampletiebar baskets
The quantity of what the sample constitutes5201lbs From where was the sample collectedSource
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Laboratory sample identification1387825-1
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-015-18 Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)SE17102987
Rebar Epoxy Batch Number(s)7996025460 Rebar Coating SpecificationASTM A775
Rebar Size (#)6 Rebar Coating ColorGreen
Rebar ManufacturerCMC,Nucor Rebar CoaterDayton Superior
Rebar Powder ManufacturerValspar Release Number1387825-1
Quality Assurance Code
Test Details
DIME Sample ID: 2018-01-19-2
DIME Test ID: 2018-01-19-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars
Test Release Date: 2018-02-01
Test Results

Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 01/25/2018
Lower spec. limit LSL: 7
Upper spec. limit USL: 16
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 0
First Bar Side 2 mean value: 0
Second Bar Side 1 mean value: 0
Second Bar Side 2 mean value: 0
First Bar Mean:0
Second Bar Mean:0
Total mean value:no data
General comments (publicly viewable) (Max 1000 characters): Epoxy flaking off, welds broken. Fail for poor workmanship.

Test was verified on 01/25/2018