Summary for Test 2018-01-09-2-7
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 211669 DEA: 022C0904 EFIS: 0200000161 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-50.6/51.7 |
Award Date | 11/16/2016 |
Closeout Date | 11/12/2020 |
Work Description | BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT |
Location Description | PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD |
QA Service Level | 1 (Verified on 10/25/2016) |
Sample Information
Sample Taken Date | 01/09/2018 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG 3/4 bolts |
The quantity of what the sample constitutes | 9 of 225 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
Title of sampler | QA Inspector | Telephone number of sampler | 510 590-0116 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S28-005-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 20334170 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 4.5 | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 3/4 | Bolt Mfg. Lot Number | G7173 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | No |
Test Details
DIME Sample ID: 2018-01-09-2
DIME Test ID: 2018-01-09-2-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-01-29
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 01/22/2018
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: G7173
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 SL
Size: .75 in
Bolt Length: 4.5 in
Measurement Average: 3.94 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/22/2018 ✔