Summary for Test 2018-01-10-6-1

Test performed: ASTM A934-13

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout DateNot set
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date01/10/2018 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/15/2018
Sample typeAcceptance A brief description of the sampleEpoxy Coated Rebar
The quantity of what the sample constitutes16088 From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQAI Telephone number of sampler707-342-8602
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameFletcher Coating Co Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-006-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)6502858502
Rebar Epoxy Batch Number(s)7G05 Rebar Coating SpecificationASTM A934
Rebar Size (#)11 Rebar Coating ColorPurple
Rebar ManufacturerGerdau Rebar CoaterFletcher Coating Company
Rebar Powder Manufacturer3M Release Number1108.E
Quality Assurance CodeA93418A09R4S17G05

Test Details

DIME Sample ID: 2018-01-10-6
DIME Test ID: 2018-01-10-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-01-25

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 01/18/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 12 mils
Bar # for First Bar: 11
Bar # for Second Bar: 11
First Bar Side 1 mean value: 10.22
First Bar Side 2 mean value: 10.24
Second Bar Side 1 mean value: 9.71
Second Bar Side 2 mean value: 9.93
First Bar Mean: 10.23
Second Bar Mean: 9.82
Total mean value: 10.03
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/18/2018