Summary for Test 2017-12-20-2-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211784 DEA: 11085784 EFIS: 1100000064 |
---|---|
DIST-CO-RTE-PM | 11-SD-163-4.1/4.9 |
Award Date | 06/16/2017 |
Closeout Date | 08/10/2021 |
Work Description | INTERCHANGE MODIFICATION AND OVERCROSSING WIDENING. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF FRIARS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 09/05/2017) |
Sample Information
Sample Taken Date | 12/20/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2018 |
Sample type | Recertification | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 1 lot | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | greg | Last name of sampler or witnessed by | johnston |
Title of sampler | QA | Telephone number of sampler | 9165247768 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rbar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L53-220-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4071355 4070468 4067791 4063303 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 4 6 8 9 |
Diameter of Hoop | 2'0' 5'0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-12-20-2
DIME Test ID: 2017-12-20-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2018-01-31
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/08/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | Cycle-1 | 100 | #9/29mm | 1 | 1 | 91107 | 91107 | NECKING OK | Fred |
General comments (publicly viewable) (Max 1000 characters): NECKING OK
Test Graph
Source: Partner Data Point FileTest was verified on 1/24/2018 ✔