Summary for Test 2017-12-27-1-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 209146
DEA: 06471504
EFIS: 0600000464
COOP: 061549
DIST-CO-RTE-PM06-TUL-99-39.6/41.3
Award Date02/24/2017
Closeout Date03/03/2020
Work DescriptionRECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT.
Location DescriptionTULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD
QA Service Level1 (Verified on 10/08/2013)

Sample Information

Sample Taken Date12/27/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/04/2018
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes12 From where was the sample collectedJob Site
First name of sampler or witnessed byJustin Last name of sampler or witnessed byPalmaymesa
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC HRC Transportation Laboratory (TL) Number982926 982927 982930
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#8,10 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)177275, 177488, A162884 Rebar Heat Number(s)4069024, 4070783
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-12-27-1
DIME Test ID: 2017-12-27-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-01-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/05/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#8/25mm0.7907418693906OK NeckingFred

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 1/5/2018