Summary for Test 2017-12-18-1-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date12/18/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/10/2018
Sample typeQuality Assurance A brief description of the sampleBarGrip XL Coupler
The quantity of what the sample constitutes1 lot From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerQA Telephone number of sampler9165247768
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSouthcoast Steel Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormL53-217-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBar Grip Intermediate Assembler or FabricatorIntegrity Rebar
Rebar Size10 Coupler ModelXL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s) 71073403 Rebar Heat Number(s)65027978
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-12-18-1
DIME Test ID: 2017-12-18-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-01-10

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/03/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#10/32mm1.27012253296482necking okayFred

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 1/3/2018